| Technical Attributes |
| Brand |
DirectLOGIC |
| Item |
PLC |
| Series |
DL05 |
| Total Memory |
6k words |
| Ladder Memory |
2k words |
| User Data Memory |
4k words |
| Programming Language |
Ladder |
| Programming Software |
DirectSOFT programming software v4.0 or later |
| Communication Port and Connection Type(s) |
|
| Port Protocol(s) |
- DirectNET
- Modbus RTU
- K-sequence
- programming and monitoring
|
| Port Speed(s) |
- fixed at 9.6k baud
- up to 38.4k baud
|
| Real Time Clock/Calendar |
No |
| Retentive Memory |
No |
| Battery Backup |
No |
| Maximum Expansion Modules Allowed |
1 |
| External Power Requirement |
12-24 VDC |
| Number of Discrete Input Points |
8 |
| Nominal Input Voltage |
12-24 VDC |
| Voltage Type |
DC |
| Discrete Input Type |
Sinking/sourcing |
| Number of Isolated Discrete Input Commons |
2 |
| Number of Points per Discrete Input Common |
4 |
| Frequency Response |
5 kHz |
| Number of Discrete Output Points |
6 |
| Nominal Output Voltage |
12-24 VDC |
| Discrete Output Type |
Sinking |
| Load Current |
1A/point |
| Number of Isolated Discrete Output Commons |
2 |
| Number of Points per Discrete Output Common |
3 |
| Maximum Switching Frequency |
7 kHz |
| Maximum Number of PID Loops |
4 |
| Number of High-Speed Capable Input Points |
3 |
| High-Speed Counter(s) |
- up to (1) up counter
- up to (1) quadrature (A and B) counter
|
| Position Scaling |
- up to (1) up counter
- up to (1) quadrature (A and B) counter
|
| Frequency Measurement |
- up to (1) up counter
- up to (1) quadrature (A and B) counter
|
| Interrupt(s) |
- up to (1) input interrupt
- up to (1) timer interrupt
|
| Number of High-Speed Capable Output Points |
2 |
| Output Pulse Mode(s) |
- up to (1) PTO linear step/direction output
- up to (1) PTO rotary clockwise/counter-clockwise (CW/CCW) output
|
| Axis Profile(s) |
- relative/absolute positioning
- velocity mode
- trapezoid
|